Knowledge · Fuel system

Short-pulse-width behaviour

Also: short pulse width adder, small pulse correction, non-linear region

Short-pulse behaviour describes how an injector deviates from its linear flow characteristic at very short opening times. ECUs compensate for it with a dedicated correction table.

Cause

At long opening times an injector behaves well: double the opening time gives roughly double the quantity. At very short opening times this no longer holds, because the needle does not reach full lift, or only briefly. HP Academy demonstrates this on an Injector Dynamics ID1050X: above about 1.5 ms, flow is linear with opening time. Below that there is not enough time to lift the needle fully off its seat, and flow deviates clearly from the ideal straight line. Within the dead time, about 0.9 ms at 14 V for this injector, no fuel flows at all.

Bosch also distinguishes between static and dynamic tolerance on high-pressure injectors. For the HDEV 6, Bosch gives ±4 per cent static and ±6 per cent at 1.5 ms opening time.

The correction in the ECU

ECUs have a dedicated table for this, which Link and Haltech call the short pulse width adder. It lengthens or shortens the opening time in the critical range so that the actual quantity matches the calculated one. According to Haltech, the values can be positive or negative, limited to ±5 ms, and the last cell of the table should be zero. HP Academy shows a correction of about 0.07 ms at 0.75 ms as an example.

Haltech stresses that this data comes from the injector manufacturer and can rarely be worked out by the user. Manufacturers such as Injector Dynamics supply such tables for common ECUs.

In practice: conversion and calibration

Short-pulse behaviour matters mainly at idle and very light part load. The bigger the injectors relative to the engine, the more often the engine operates there. HP Academy rates short-pulse data as nice to have and dead-time data as essential. Without short-pulse data, idle calibration gets harder, but not impossible.

Common mistakes

  • Errors in the short-pulse range worked into the VE table. HP Academy describes how this makes the table irregular.
  • Data entered in the wrong unit. In one ECU software package HP Academy found the table in per cent where milliseconds were meant.
  • Dead time and short-pulse correction mixed from different sources.

Want this on your car?

Calibration remotely via datalogs or on the dyno, with Link, Haltech, MaxxECU, Ecumaster or EcuTek. Send me vehicle, ECU and goal.

Get in touch

Last updated:

Kronshorst (Brunsbek) · near Hamburg, Germany

Contact

Project, datalog or question: get in touch directly by phone, WhatsApp or email.

What I need for a quote

  • Car, engine and year
  • ECU: make, model, firmware (or factory ECU)
  • Modifications: turbo, injectors, fuel pump, sensors, intercooler
  • Fuel, e.g. 98 RON or E85
  • Use: road, track days or motorsport
  • Existing calibrations and datalogs; has another tuner worked on it?
  • Preferred: dyno or remote

Enquiry by emailEnquiry via WhatsApp

The buttons open a pre-filled message with these points.