Injector dead time
Also: injector latency, injector lag, battery offset, injector offset
Dead time is the delay between energising an injector and the start of fuel flow. The ECU adds it to every calculated opening time.
What happens
Haltech describes dead time as the mechanical delay between energising the coil and fuel actually starting to flow. During this time the magnetic field builds and the needle lifts, but no fuel flows yet. The ECU therefore has to add this time on top of the calculated opening time.
Dependence on voltage and pressure
Dead time rises markedly when system voltage drops. It also depends on the differential pressure the needle has to open against. HP Academy quotes about 0.925 ms at 14 V and about 1.955 ms at 8 V for the Injector Dynamics ID1050X.
Manufacturers therefore supply dead time as a table against voltage, often against differential pressure as well. Haltech recommends getting the data from the injector manufacturer or supplier.
Why it matters for calibration
At idle and light part load the opening times are short and dead time makes up a large share. A dead-time error therefore has its biggest effect there. HP Academy shows that a wrong curve shape already makes the mixture drift when voltage drops from 14 to about 13 V under load.
Without manufacturer data, any dead time is an estimate. HP Academy suggests about 0.75 to 0.85 ms at 14 V as a starting point for unknown injectors, keeping the typical curve shape, and describes a test at reduced voltage. Fuel pressure can drop during such a test too, which distorts the result. This is therefore only a fallback.
Common mistakes
- A single value entered instead of a curve against voltage.
- Dead-time errors compensated in the VE table. That only fits at one voltage.
- Data copied from a similar injector.
- Pressure influence ignored on returnless systems.
FAQ: Injector dead time
Can I compensate a wrong dead time in the VE table?
Only for one voltage. When system voltage changes, the error returns. HP Academy describes how VE values tuned at low voltage cause errors once voltage recovers.
Want this on your car?
Calibration remotely via datalogs or on the dyno, with Link, Haltech, MaxxECU, Ecumaster or EcuTek. Send me vehicle, ECU and goal.