Injector flow rate (static flow)
Also: static flow, injector size, flow rating
Flow rate states how much fuel an injector held fully open passes per minute. The figure only applies at a specific differential pressure and with a specific test fluid.
What the figure means
Static flow is measured with the injector held open. Common units are cm³/min, usually written cc/min, as well as lb/hr and g/min. Haltech uses cc/min as the default unit in its software and notes that most injectors are rated in cc/min or lb/hr.
The test conditions are part of the figure. Bosch gives EV14 values in cm³/min and in g/min, each at 3 bar with n-heptane as the test fluid. The number in a product name is not automatically the flow at your system pressure either: HP Academy quotes 1065 cm³/min at 43.5 psi for the Injector Dynamics ID1050X.
Dependence on pressure
Flow rises with differential pressure, but less than the pressure itself. Haltech’s example is an injector flowing 1035 cm³/min at 45 psi and 1085 cm³/min at 50 psi. Just over 11 per cent more pressure therefore brings just under 5 per cent more flow.
Haltech therefore recommends entering flow values for several differential pressures if the manufacturer supplies them. This matters most on returnless systems: there, rail pressure stays fixed and, according to HP Academy, injector flow changes with manifold pressure.
In practice: conversion and calibration
In the ECU the flow rate is the scale for the entire fuel calculation. If it is wrong, the mixture is off by roughly the same factor everywhere, and during calibration the error ends up in the VE table. That works until someone changes the injectors or the fuel pressure.
If several injectors share one output, Haltech says to enter their combined flow. More system pressure is no good substitute for bigger injectors: the flow gain is small, and the pump delivers less at higher pressure.
Common mistakes
- Flow entered for a different reference pressure than the actual differential pressure.
- cm³/min, lb/hr and g/min mixed up.
- Wrong flow compensated in the VE table instead of correcting the value.
- Value taken from the product name instead of the data sheet.
Related terms
- Fuel injector
- Fuel pressure and differential pressure
- Injector pulse width and duty cycle
- Injector dead time
Related guides
Related engines
Fuel system fundamentals → Glossary A–Z →
Sources (6)
- https://support.haltech.com/portal/en/kb/articles/flow
- https://support.haltech.com/portal/en/kb/articles/why-you-need-a-fuel-pressure-regulator
- https://www.bosch-motorsport.com/products/fuel-and-spark/injection-valves/injection-valve-ev-14/
- https://www.bosch-motorsport.com/media/catalog_content/downloads_catalog/pdf_catalog/data_sheet_67797771_injection_valve_ev_14.pdf
- https://www.hpacademy.com/previous-webinars/407-injector-characterisation-haltech-nsp/
- https://aftermarket.tiautomotive.com/wp-content/uploads/2024/06/F90000274-Flow-Curve.pdf
Want this on your car?
Calibration remotely via datalogs or on the dyno, with Link, Haltech, MaxxECU, Ecumaster or EcuTek. Send me vehicle, ECU and goal.
Last updated: