Knowledge · Cooling & lubrication

Radiator fan and fan control

Also: electric fan, viscous fan, thermo fan, fan output

The radiator fan moves air through the radiator when ram air is not enough, especially when stationary or at low speed. It is controlled by a temperature switch, a viscous clutch or the ECU.

Types

Mechanical fans are belt-driven by the engine, often through a fan clutch that slips at low temperature to save power. Electric fans are switched by a thermostatic switch or the engine ECU. They provide good airflow even at low engine speed and when stationary.

At high speed, ram air is usually sufficient, which is why Haltech offers a fan disable above an adjustable road speed. The fan matters mainly when stationary, in the paddock, in the pit lane and on the dyno.

Control by the ECU

On Link the fan is run through a relay on an auxiliary output. Switch-on temperature and hysteresis are set. HP Academy shows an example with a switch-on temperature of 94 °C and the default hysteresis of 2 degrees: the fan runs from 94 °C and switches off again at 92 °C. A time-out with the engine stopped prevents the fan from flattening the battery.

Haltech supports up to four fans with their own enable and disable thresholds, PWM control at typically 200 to 500 Hz, linking to the air conditioning and switching off above a road speed. Target idle speed can be raised while the fan runs. MaxxECU shows an example with two fans switching in at 86 °C and 90 °C.

In practice: conversion and calibration

A fan with a high current draw loads the electrical system and alternator when it switches on, and so affects idle. Haltech therefore offers a delay that applies the idle-up shortly before the fan engages, so idle control has already reached the new target. Injector dead time is stored in the ECU against battery voltage. According to HP Academy, the mixture only stays stable as battery voltage fluctuates if this table matches the injectors fitted. Both can be checked by switching the fan on and off at idle while logging engine speed, voltage and lambda.

Common mistakes

  • No hysteresis set, so the relay cycles constantly.
  • Fan fitted without a shroud or with gaps, so it recirculates air.
  • Failed fuse, relay, temperature sensor or wiring. HELLA lists these causes for fans that do not switch on.
  • Fan keeps running after shutdown and drains the battery.

Want this on your car?

Calibration remotely via datalogs or on the dyno, with Link, Haltech, MaxxECU, Ecumaster or EcuTek. Send me vehicle, ECU and goal.

Get in touch

Last updated:

Kronshorst (Brunsbek) · near Hamburg, Germany

Contact

Project, datalog or question: get in touch directly by phone, WhatsApp or email.

What I need for a quote

  • Car, engine and year
  • ECU: make, model, firmware (or factory ECU)
  • Modifications: turbo, injectors, fuel pump, sensors, intercooler
  • Fuel, e.g. 98 RON or E85
  • Use: road, track days or motorsport
  • Existing calibrations and datalogs; has another tuner worked on it?
  • Preferred: dyno or remote

Enquiry by emailEnquiry via WhatsApp

The buttons open a pre-filled message with these points.