Valve timing and duration
Also: cam duration, valve events, IVO, IVC, EVO, EVC
Valve timing states at which crank angle the intake and exhaust valves open and close. Duration is the crank angle over which a valve is open, measured from a defined minimum lift.
The four events
Intake opens, intake closes, exhaust opens, exhaust closes: these four events are given in crank degrees before or after the dead centres. The MIT lecture gives intake closing at 30 to 50 degrees after bottom dead centre and exhaust opening 30 to 50 degrees before it for passenger car engines.
Intake closing has the biggest effect on cylinder filling. If the valve closes late, the engine uses the inertia of the charge at high engine speed. At low engine speed the piston pushes charge back out instead, and dynamic compression drops. It falls with late intake closing.
How duration is measured
Because the ramps lift the valve very slowly, duration depends heavily on the lift from which it is counted. The usual checking height is about 1.3 mm (0.050 inch). The Kelford cam card shown by HP Academy quotes figures at 0.1 mm and 1 mm and shows how big the difference is: 284 degrees at 0.1 mm, 254 degrees at 1 mm. HP Academy prefers the 1 mm figure because the ramps distort the 0.1 mm value.
In practice: selection and calibration
Longer duration brings power at high engine speed and costs torque at low speed. Camshafts can therefore only be compared if the figures are quoted at the same checking height. Overlap also increases with longer duration if the lobe separation stays the same. Overlap is what most affects idle quality.
Common mistakes
- Figures at 0.1 mm, 1 mm and 1.3 mm (0.050 inch) compared directly.
- Looking only at duration and overlooking intake closing.
- A cam with late intake closing fitted to a low-compression engine without considering dynamic compression.
Want this on your car?
Calibration remotely via datalogs or on the dyno, with Link, Haltech, MaxxECU, Ecumaster or EcuTek. Send me vehicle, ECU and goal.