Knowledge · Fuel system

Wideband lambda sensor

Also: wideband, wideband O2 sensor, UEGO, LSU

A wideband lambda sensor measures exhaust lambda across a wide range from rich to lean. It needs its own controller to run the measuring cell and heater.

Difference from a narrowband sensor

A narrowband sensor switches around lambda 1: it outputs about 0.2 V when lean and about 0.8 V when rich. In between its signal is not linear. That is enough for closed-loop control at lambda 1, but not for full-load calibration.

The wideband sensor has an additional pump cell. A control loop adjusts the pump current so that the measuring cell output stays constant. The pump current then directly indicates the oxygen content of the exhaust. This needs a controller with suitable electronics. For the LSU 4.9, Bosch specifies a dedicated LSU chip.

Key data: the LSU 4.9 as an example

For the LSU 4.9, Bosch specifies among other things:

  • Measuring range from lambda 0.65 to free air.
  • Exhaust temperature in operation below 930 °C, briefly below 1030 °C, at the hexagon below 600 °C.
  • Exhaust pressure no more than 2.5 bar, higher pressure reduces accuracy.
  • Steady-state heater power 7.5 W.
  • Approved for petrol, diesel and E85.

Installation and signal transmission

Bosch recommends mounting the sensor as vertically as possible with the cable pointing up, where the exhaust gas is as hot as possible, away from the tailpipe and protected from condensation. The exhaust passage upstream must be leak-free. On turbo engines, pressure and temperature are higher upstream of the turbine than downstream. Given the sensor’s limits, that is an argument for mounting it downstream of the turbo.

The controller transmits the reading either as an analogue signal or digitally over CAN. CAN transmits digitally over a differential pair. Conversion errors of analogue transmission disappear, and a ground offset between devices does no harm within the specified range. Link lists onboard digital wideband lambda control for the G5 Voodoo Neo 4 and two onboard lambda controllers for the G5 Voodoo Pro.

Common mistakes

  • Sensor fitted where exhaust pressure or temperature exceeds its limits.
  • Leaks at the manifold or flange upstream of the sensor overlooked.
  • Analogue signal read with a wrong ground reference or wrong calibration.
  • Sensor damaged by leaded fuel, silicone or oil burning.

Want this on your car?

Calibration remotely via datalogs or on the dyno, with Link, Haltech, MaxxECU, Ecumaster or EcuTek. Send me vehicle, ECU and goal.

Get in touch

Last updated:

Kronshorst (Brunsbek) · near Hamburg, Germany

Contact

Project, datalog or question: get in touch directly by phone, WhatsApp or email.

What I need for a quote

  • Car, engine and year
  • ECU: make, model, firmware (or factory ECU)
  • Modifications: turbo, injectors, fuel pump, sensors, intercooler
  • Fuel, e.g. 98 RON or E85
  • Use: road, track days or motorsport
  • Existing calibrations and datalogs; has another tuner worked on it?
  • Preferred: dyno or remote

Enquiry by emailEnquiry via WhatsApp

The buttons open a pre-filled message with these points.