Compressor choke
Also: choke line, choke flow, stonewall
The choke line is the right-hand boundary of the compressor map. There the compressor can barely move more air despite rising speed, and its efficiency collapses.
What choke means
On the right of the map, the lines of constant turbo speed crowd together. More speed there brings hardly any more flow. On its own maps, Garrett usually defines the choke line as the point where efficiency drops below 58 per cent. In this region the turbo also approaches its speed limit.
Low efficiency means a lot of heat for little extra pressure. Air leaves the compressor much hotter, the intercooler has to do more and the tendency to knock rises.
How it shows
A turbo at choke holds boost poorly at high rpm, and power flattens or drops. In Garrett’s worked example, a compressor with a 60 mm wheel sat beyond the choke line for a 400 hp target on both the 2.0-litre and the 5.0-litre engine. Beyond this limit, according to Garrett, turbo speed rises quickly and overspeed becomes likely.
In practice: conversion and calibration
No solenoid and no table helps against choke. If the operating points at maximum rpm run off the right side of the map, the compressor is too small for the target. The options are then a bigger compressor, a lower power target or boost that tapers towards maximum rpm. Because efficiency collapses there, the datalog shows intake air temperature rising while boost no longer increases.
Common mistakes
- More boost run although the compressor is already at choke.
- Rising charge temperature blamed on the intercooler alone.
- Turbo chosen by pressure ratio only, without checking flow at maximum rpm.
Related terms
Related guides
Want this on your car?
Calibration remotely via datalogs or on the dyno, with Link, Haltech, MaxxECU, Ecumaster or EcuTek. Send me vehicle, ECU and goal.
Last updated: