Rev limiter

Also: rpm limiter, rev limit

The rev limiter keeps engine speed below a limit by cutting ignition, fuel or both. According to Link, it protects against valve float and con rod failure.

How it works

When the engine reaches the limit, the ECU skips individual combustion events. With a hard cut, according to Haltech, all injection or ignition outputs are disabled above the limit. With a soft cut, the ECU randomly cuts individual outputs so that rpm stays near the limit. Haltech also has a third type in which, according to HP Academy, the cut rises from zero to 100 per cent over an adjustable range. In the HP Academy example, a 7000 rpm limit with a 500 rpm range starts cutting from 6500 rpm.

Ignition or fuel cut

Opinions differ here, even within HP Academy. The launch control course says ignition cut usually gives the best results and is needed if boost is to be built while stationary using ignition retard. In the webinar on rpm limit configuration with a Haltech ECU, on the other hand, the presenter almost always uses fuel cut.

Both sources agree on the risk. With ignition cut, unburnt mixture reaches the exhaust and can ignite there. On sensitive valve trains such as the SR20DET or 4G63, according to HP Academy, this can dislodge rockers or briefly lift exhaust valves off their seats. For such engines both sources recommend fuel cut.

In practice

For the first runs, the presenter in the HP Academy webinar sets the limit low, 4000 to 5000 rpm in the example, and raises it only once the engine runs as expected. This is an example value, not a general recommendation. A limit against coolant temperature stops a cold engine from being revved too hard. Link also lists further rpm limits that can be tied to conditions such as oil pressure, and separate limiters for launch and burnout.

The limit itself is set by the engine, not the ECU. It is based on the data from the engine manufacturer or engine builder.

Typical problems

  • Hard cut in daily use: according to HP Academy it feels very harsh.
  • Ignition cut on engines with sensitive valve trains or hydraulic lifters such as the 4G63.

Want this on your car?

Calibration remotely via datalogs or on the dyno, with Link, Haltech, MaxxECU, Ecumaster or EcuTek. Send me vehicle, ECU and goal.

Get in touch

Last updated:

Kronshorst (Brunsbek) · near Hamburg, Germany

Contact

Project, datalog or question: get in touch directly by phone, WhatsApp or email.

What I need for a quote

  • Car, engine and year
  • ECU: make, model, firmware (or factory ECU)
  • Modifications: turbo, injectors, fuel pump, sensors, intercooler
  • Fuel, e.g. 98 RON or E85
  • Use: road, track days or motorsport
  • Existing calibrations and datalogs; has another tuner worked on it?
  • Preferred: dyno or remote

Enquiry by emailEnquiry via WhatsApp

The buttons open a pre-filled message with these points.