Wiring basics: cable sizes for engine management

A standalone ECU is only as reliable as its wiring harness. This guide shows you how to choose cable sizes by current and voltage drop, which cable types are available, and how to execute and test earthing, shielding, fusing, connectors and routing to manufacturer guidance. Every figure is given with its source, and worked examples are marked as examples.

Cross-section in mm² and AWG

In Europe conductor size is given in mm²; wire from US motorsport and aerospace is sized in AWG. The smaller the AWG number, the larger the conductor. The values below are the nominal AWG areas (according to the Farnell AWG conversion table) and the areas a manufacturer quotes for SAE J1128 wire (according to the IEWC TXL/GXL/SXL data sheet).

ISO 6722 uses metric sizes only: 0.13, 0.22, 0.35, 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 10, 16, 25, 35, 50, 70, 95 and 120 mm² (per ISO 6722, Table 4). An AWG size therefore never matches an ISO size exactly. When you convert, check current and voltage drop again using the actual cross-section.

AWGNominal area mm²Diameter mmSAE J1128 (IEWC) mm²Nearest ISO 6722 size mm²
240.2050.511–0.22
220.3260.644–0.35
200.5180.8120.5080.5
180.8231.0240.760.75
161.311.2911.121.5
142.081.6281.852
123.312.0532.913
105.262.5884.655
88.373.2647.2310

Columns 2 and 3 from the Farnell AWG conversion, column 4 from the IEWC SAE J1128 data sheet, ISO sizes per ISO 6722 Table 4. The last column is our own mapping to the numerically nearest value and may be smaller than the AWG area.

Cable types

FLRY is the common European automotive cable with PVC insulation. The data sheet cites ISO 6722-1, DIN 72551-6 and ECE-R 118 and a temperature range of −40 °C to +105 °C (according to the TME FLRY data sheet). ISO 6722 groups cables into temperature classes, for example class B at −40 °C to 100 °C, class C up to 125 °C and class D up to 150 °C (per ISO 6722, Table 1).

TXL, GXL and SXL are cross-linked cables to SAE J1128 rated −40 °C to +125 °C. They differ in wall thickness: for 20 to 14 AWG the data sheet gives 0.28 to 0.40 mm for TXL and 0.41 to 0.58 mm for GXL (according to the IEWC SAE J1128 data sheet).

TE/Raychem Spec 55 to M22759/32 (often called Tefzel) has cross-linked modified ETFE insulation with a 0.152 mm nominal wall, a tin-coated copper conductor, a 600 V rating and a range of −65 °C to 150 °C (according to the AWC 55A0111/M22759/32 data sheet). The thin wall saves weight and diameter but needs suitable seals in connectors (according to the HP Academy Deutsch DT guide).

DR-25 is an elastomeric heat-shrink tubing used as harness jacket: −75 °C to +150 °C, 2:1 shrink ratio, full recovery at 175 °C, splash resistance to fuel, brake fluid, hydraulic fluid, lubricating oil and water (according to the TE DR-25 data sheet). TE describes it as chemical and abrasion resistant (according to TE, Harnessing Tubing).

TypeStandard/specificationTemperature rangeSource
FLRYISO 6722-1, DIN 72551-6−40 °C to +105 °CTME data sheet
TXL / GXL / SXLSAE J1128−40 °C to +125 °CIEWC data sheet
Spec 55 (55A0111)M22759/32−65 °C to 150 °CAWC data sheet
DR-25 (jacket)TE product specification−75 °C to +150 °CTE data sheet

Examples of construction types, not product recommendations. The data sheet of the cable you actually fit is what counts.

Current rating and bundling

How much current a cable may carry continuously depends on cable type, temperature class, ambient temperature and bundling. In a bundle and in a hot engine bay the permissible load is much lower than for a single wire in free air. Binding values are in the datasheet of the cable you actually fit; there is no generally valid table for FLRY or TXL in a bundle at engine-bay temperature that could be quoted reliably here.

For most signals and small loads, 20 or 22 AWG is enough according to HP Academy. Fuel pump, fans and some ignition components need a larger cross-section (according to HP Academy). According to HP Academy, you determine the current of a load with Ohm’s law from system voltage and the load’s resistance.

In practice, on long runs it is usually voltage drop rather than heating that sets the cross-section. The next section shows how to calculate it.

Calculating voltage drop

Besides heating, voltage drop limits the cross-section. For feed and return conductors of equal length ΔU = 2 · I · ρ · l / A, with ρ = 0.0178 Ω·mm²/m for copper, I in A, l as the one-way length in m and A in mm². If the return runs through the chassis, the factor 2 drops out for the cable, but the contact resistance of the earth connection is added.

Cross-check against the data sheet: for 1.5 mm² the formula gives 0.0178 / 1.5 = 11.9 mΩ/m. The FLRY data sheet gives a conductor resistance of 12.7 mΩ/m at 20 °C (according to the TME FLRY data sheet). The formula is therefore slightly optimistic, and resistance rises further with temperature.

Fuel pump example (example values: 15 A, 5 m one-way, feed and return): ΔU = 2 · 15 · 0.0178 · 5 / 2.5 = 1.07 V with 2.5 mm² and 0.67 V with 4 mm². Delphi specifies less than 0.2 V on the positive side and less than 0.2 V on the earth side of the pump circuit (according to Delphi). Achieving 0.2 V on the 5 m positive feed alone would need 15 · 0.0178 · 5 / 0.2 = 6.7 mm², i.e. the 10 mm² ISO size. Length dominates: a short feed from a relay near the pump helps more than a heavier cable along the whole car.

ExampleI (A)l (m)A (mm²)ΔU (V)ΔU at 14 V
Fuel pump1552.51.077.6 %
Fuel pump15540.674.8 %
Fan201.52.50.433.1 %
ECU supply1021.50.473.4 %
Injector 12 Ω1.1720.50.171.2 %
Injector 12 Ω1.1720.750.110.8 %

All currents and lengths are example values, not measurements. Injector current calculated as 14 V / 12 Ω = 1.17 A (system voltage 13.8 to 14.2 V according to HP Academy). ΔU = 2 · I · 0.0178 · l / A; connectors and relay contacts are not included.

Supply, fusing and relays

A fuse is fitted primarily to protect the wire, and its rating is matched to the rating of the wire it protects (according to Blue Sea Systems). It is the intentional weak link in the circuit (according to Littelfuse) and stops short-circuit current from overheating components and wiring (according to HP Academy). Littelfuse recommends operating a fuse at no more than 75 % of its rated current, and less at higher ambient temperature (according to the Littelfuse Fuseology guide).

The ECU main supply goes to the battery, not the ignition switch, by the shortest route to the positive terminal (according to Haltech). MoTeC requires at least 12 AWG (3.3 mm²) for the ECU supply, a 30 A relay and a 20 A fuse, switched via the ignition switch, because the switch probably cannot handle the current (according to the MoTeC M84 manual). Supply injectors, ignition, ECU and auxiliaries through relays fed from a fuse box connected directly to the battery positive (according to the Haltech E8 manual).

  • Keep the cable from battery to fuse box short and protect it against insulation damage, since it is unfused (according to the Haltech E8 manual).
  • Do not tap any wire that happens to show ignition 12 V (according to the Haltech E8 manual).
  • Connect the fuel pump via the fuel pump relay (according to the Haltech E8 manual).
  • Derive cable size and fuse for fans, pump and coils from the load's data sheet and the cable's current rating, not the other way round.

Earthing

Haltech recommends a single earth reference point (star point) to which all earths return. Engine, chassis or battery negative are candidate locations; Haltech usually prefers the cylinder head because it minimises the chance of a voltage drop causing random ignition events (according to Haltech, ECU Grounding). For the battery ground wire of individual Haltech ECUs, however, Haltech specifies a direct connection to battery negative (according to the Haltech KB). The manual for your ECU takes precedence.

MoTeC requires the ECU and ignition earths on the engine block, at least 12 AWG (3.3 mm²) and as short as possible (according to the MoTeC M84 manual).

  • Connect sensors only to the ECU's sensor ground, with no extra earth wire from the sensor to the engine (according to Haltech).
  • Do not earth the ECU to both engine and battery, otherwise starter current can flow through the ECU earth (according to Haltech).
  • Keep coils and ECU at the same earth potential. Haltech mentions coils that can fire from a difference of about 0.7 V (according to Haltech).
  • Sensors that earth through their body (some cam sensors, narrowband oxygen sensors, many knock sensors): either replace them with versions that have their own earth wire or place the star point on the engine (according to Haltech).
  • No paint, anodising or thread-locking compound between ring terminal and earth point; use a proper ring terminal (according to the Haltech KB and the MoTeC M84 manual).

Shielding

Crank and cam speed and position signals should always run in shielded cable, as should other low-level signals such as knock sensors and exhaust gas thermocouples (according to HP Academy, Shielded Cable). Haltech, for example, runs the trigger and home signals of a trigger wheel in shielded 4-core cables (according to the Haltech KB, TB48).

Terminate the shield at one end only, because a shield connected at both ends forms an earth loop (according to HP Academy). The ECU end is usual: use the ECU's dedicated shield pin if it has one, otherwise one of the ECU power grounds (according to HP Academy). Leave the sensor end open. Link ECUs show dedicated Shield/Gnd pins next to the trigger and knock inputs in their loom diagrams (according to the Link Storm X Quickstart Guide). Where the manufacturer specifies otherwise, follow the manufacturer.

Connectors and crimping

Choose a connector by contact current, conductor size and insulation diameter. The table lists construction examples from manufacturer documents. For DT connectors TE gives −55 °C to +125 °C and at least 100 mating cycles (according to the TE/Deutsch DT data sheet). Superseal 1.5 is rated for 0.35 to 2.5 mm², 14 A maximum and −40 °C to +125 °C (according to TE via TTI).

Crimp each contact with the tool intended for it. Pull-test a sample of wire and contact: the wire should break before it pulls out of the crimp. Test with exactly the wire size you are fitting, as most tools only cover a range (according to the MoTeC M84 manual). Pull on wire and contact after every crimp (according to the Haltech E8 manual). Soldering crimp contacts is a last resort, because solder creates a stress point and flux can cause corrosion (according to the MoTeC M84 manual).

TypeContact sizeCurrent per contactConductor rangeSource
DTM207.5 A22 to 16 AWG (0.5 to 1.5 mm²)TE/Deutsch DT data sheet
DT1613 A20 to 14 AWGTE/Deutsch DT data sheet
DTP1225 A14 to 10 AWGTE/Deutsch DT data sheet
Superseal 1.5–max. 14 A0.35 to 2.5 mm²TE via TTI

DT ratings are continuous at 125 °C according to the data sheet. HP Academy gives 22 to 14 AWG for DTM, the TE data sheet 22 to 16 AWG: if in doubt, the current TE data sheet applies.

Routing

  • Keep ECU wiring at least 100 mm from spark plug leads wherever possible, and cross them at right angles where unavoidable (according to the MoTeC M84 manual).
  • Do not run wiring next to starter cables, ignition coils and their wiring, and keep it away from radio transmitter antenna cables and high-power audio systems (according to the Haltech E8 manual).
  • Mount the ECU physically separated from ignition components (according to the Link Storm X Quickstart Guide).
  • Do not use unsuppressed spark plugs and HT leads; they can disrupt the ECU (according to the Haltech KB).
  • Keep wiring away from heat sources and add heat shielding where needed (according to the Haltech KB). Check the cable's temperature class against the location (per ISO 6722).
  • Add an abrasion-resistant jacket at chafe points, for example an elastomeric heat-shrink of the DR-25 type (according to TE).

Testing

A resistance meter often only reveals a poor crimp or a corroded earth under current. Measure the voltage drop with the load running. Delphi describes this for the fuel pump: meter on 20 V DC, measure battery positive against the feed at the pump connector, then the earth terminal at the pump connector against battery negative, each with the pump running. Both readings should be below 0.2 V (according to Delphi).

Do not push probes into the terminals. Touch the side of the terminal or, better, use a mating connector (according to the MoTeC M84 manual). After installation, check that no wiring has been left uninsulated (according to the Haltech KB).

  • Positive side: battery positive against positive at the load, load switched on.
  • Earth side: earth at the load against battery negative, load switched on.
  • Compare readings with the calculation from the voltage drop section. A clearly higher value points to contact resistance at a crimp, connector, relay or earth.

Sources

  1. Farnell: AWG Conversion Calculator
  2. IEWC: SAE J1128 wires (GXL, SXL, TXL), Datenblatt
  3. TME: FLRY-Datenblatt (ISO 6722-1, DIN 72551-6)
  4. ISO 6722:2006, Vorschau (iTeh Standards)
  5. TE Connectivity: Harnessing Tubing (DR-25)
  6. TE Connectivity: DR-25-3/4-0-SP Datenblatt
  7. HP Academy: How do I select the right wire gauge/size?
  8. HP Academy: Wiring Fundamentals, Shielded Cable
  9. HP Academy: Crank & Cam Angle Sensor Wiring, Shielded Cable Grounding
  10. HP Academy: Wiring Fundamentals, Fuses
  11. HP Academy: Deutsch DT Series Connector Guide
  12. Haltech: ECU Grounding, the Do's and Don'ts
  13. Haltech KB: Black (Battery Ground)
  14. Haltech KB: Flying Lead Loom Installation on bare engine
  15. Haltech KB: Before You Begin
  16. Haltech KB: TB48 Trigger Information
  17. Haltech E8/E11v2 Handbuch, Installation
  18. MoTeC M84 Handbuch, Power wiring, Spark plug leads, Terminal crimping
  19. Link Engine Management: Storm X Quickstart Guide G4X
  20. TE/Deutsch: DT Series Datenblatt (Digi-Key)
  21. TE AMP Superseal 1.5 (TTI)
  22. Blue Sea Systems: Choosing Circuit Protection
  23. Littelfuse: Fuseology Design Guide
  24. Delphi: How to perform a voltage drop test

All guides →

Kronshorst (Brunsbek) · near Hamburg, Germany

Contact

Project, datalog or question: get in touch directly by phone, WhatsApp or email.

What I need for a quote

  • Car, engine and year
  • ECU: make, model, firmware (or factory ECU)
  • Modifications: turbo, injectors, fuel pump, sensors, intercooler
  • Fuel, e.g. 98 RON or E85
  • Use: road, track days or motorsport
  • Existing calibrations and datalogs; has another tuner worked on it?
  • Preferred: dyno or remote

Enquiry by emailEnquiry via WhatsApp

The buttons open a pre-filled message with these points.